Titan

Technical spec sheet
400-500-600kVA






 

 








 


 

 

 

 

 

 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 




 

 

 

 

 


BPEE Titan UPS offers professional users a top performance power protection solution. With its latest Input Power Factor Correction (IPFC) technology, BPEE Titan UPS protect data, information exchange and Internet connections to maximize the efficiency of medium to large sized networked organizations.

The Titan series UPS is equipped with the latest Input Power Factor Correction (IFPC) technology. The IFPC has pushed the edge for input performance in the industry (THDI <4%). The power factor of the Hyperion UPS is closed to unity, even at low loads.

BPEE has also integrated series of industry-leading technology, such as "
HyperRing Data Bus

Inverter PowerMan
Feed-forward Control
Controlled WarmUp

Software and Management BPEE UPS have comprehensive software and management system to suit our customers' needs
   
   
   
   
   
   
   
   
   
   
--------------------------------------------------------------------------------

HyperRing Data Bus
BPEE has developed a unique technology for managing UPS data exchange - a digital HyerRing bus network which connects multiple BPEE UPS. Using this data bus network, BPEE UPS work together under all modes of parallel operation.

Hot plug

The major advantage of having the comunication bus in a ring circuit is that it tolerates disconnection at any point on the circuit. Any UPS on the bus can thus be completely disconnected and removed from the circuit without affecting the operation of other units on the Ring. Total isolation of failed unit or hot-plugging a unit on and off the network can be achieved.

   
   
   
--------------------------------------------------------------------------------

Inverter PowerMan System

By utilizing the digital control system, BPEE UPS incorporate intelligent PowerMan program, to provide complite protection to both the load and the UPS itself during overload and over-current conditions.

The PowerMan program monitors the maximum permitted power dissipation of every inverter power component - expecially IGBT. Once overload is detected, the system will stop the inverter to preventdamages of the power component.

   
   
   
--------------------------------------------------------------------------------

Inverter Feed-forward control

To further improve the inverters' dynamic response, BPEE UPS implement the feed-forward control. This feed the variations of the input directly to the output before any change in the output has been detected via the feedback ontrol loop, significantly improving inverter output stabiliy.

   
   
   
   
--------------------------------------------------------------------------------

Soft start with control 'warm up'

Whenever the rectifier of an BPEE UPS is restarted, the control loop and logic undergo a 'warm up' sequence. Following this, current is gradually taken from the input to prevent inrush input current. In addition, there is no over-shooting of the DC voltage after the 'warm up'.